4130 Tubing Joint Tensile Strength Test



A cluster of 3/4in by .035 4130 tubing welded with 1/16th ER70S-6 being pulled apart to failure. It yielded at 7550lbs along the longitudinal axis of the uncut tubing and not at either weld on the T joint.


Post time: Jun-22-2017